40 AWG Bifilar Parallel Type T Thermocouple Wire for Cryogenic Temperature Measurement and Copper Constantan Thermocouple Cable Applications

Place of Origin Shanghai, China
Brand Name Huona
Certification ISO 9001, RoHS, Material Test Report
Model Number T-40AWG-BF-20CM-02
Minimum Order Quantity 10 pieces
Price Negotiable, based on quantity and termination
Packaging Details Sealed bag with batch label, inner box, export carton
Delivery Time 7-12 working days after payment
Payment Terms T/T,L/C at sight,Western Union
Supply Ability 500,000 pieces per month
Product Details
Thermocouple Type Type T (Copper / Constantan CuNi45) Wire Gauge 40 AWG
Conductor Diameter 0.076 Mm Temperature Range -200 To 350 Deg C
Accuracy Class Class 1, +/-0.5 Deg C Or +/-0.4% Lead Length 20 Cm
Conductor Configuration Bifilar Parallel Bonded, Twin Conductor Hot Junction Welded Bead
Highlight

cryogenic thermocouple wire

,

type T low temperature sensing

,

copper constantan bifilar wire

Leave a Message
Product Description

Product Overview

Accurate temperature measurement is essential in cryogenic research, low-temperature testing and specialized cooling systems. In these applications, the sensing element must be compact, thermally responsive and suitable for installation in confined spaces such as cryostats, vacuum chambers and laboratory cooling assemblies.

Our 40 AWG Type T Bifilar Thermocouple Wire is a miniature temperature sensing assembly designed for low-temperature measurement and cryogenic research applications.

The assembly consists of two individually insulated conductors arranged side by side in a parallel configuration. The positive conductor is made of copper with blue insulation, while the negative conductor is made of Constantan (copper-nickel alloy, CuNi45) with red insulation.

A factory-welded hot junction is provided at the measuring end, allowing convenient integration into cryogenic temperature probes, laboratory testing fixtures and customized sensing assemblies.

With its ultra-fine conductor construction, compact parallel geometry and pre-welded measuring junction, this product is suitable for applications requiring small sensing dimensions, low thermal mass and flexible installation in specialized low-temperature environments.

Key Features & Advantages

1. Type T Thermocouple for Low-Temperature Measurement

Type T thermocouples combine a copper positive conductor with a Constantan negative conductor.

They offer useful thermoelectric sensitivity and well-established reference characteristics over a broad temperature range, making them suitable for refrigeration, cryogenic research, low-temperature laboratories and precision temperature measurement.

Type T is particularly useful for applications involving sub-zero temperatures and liquid nitrogen temperature environments.

2. Ultra-Fine 40 AWG Conductor Design

The 40 AWG miniature conductor construction provides a small physical footprint and low thermal mass.

The fine wire helps reduce heat conduction along the leads and minimizes the physical impact of the sensing element on small measurement targets.

This is particularly useful when measuring localized temperatures on cold fingers, cryostat stages, laboratory specimens and compact cooling components.

3. Bifilar Parallel Wire Construction

The two insulated conductors are arranged closely side by side along their length.

This parallel configuration helps minimize the effective electrical loop area and can reduce susceptibility to induced electromagnetic interference compared with widely separated leads under comparable installation conditions.

The compact profile also facilitates installation through narrow cryostat openings, feedthrough assemblies and confined laboratory fixtures.

For environments involving superconducting magnet power supplies or RF heating equipment, appropriate shielding, grounding and lead routing should also be considered.

4. Factory-Welded Hot Junction

Each assembly features a factory-welded hot junction at the measuring end.

The pre-welded configuration eliminates the need for customers to manufacture the measuring junction during downstream assembly, helping simplify installation and improve consistency between sensor assemblies.

The junction can be attached to a measurement surface or incorporated into a suitable protective structure using compatible low-temperature adhesives, varnishes or cryogenic encapsulation materials.

5. Low Thermal Mass for Cryogenic Applications

The ultra-fine conductor design helps reduce the thermal mass of the sensing element and heat conduction along the thermocouple leads.

This is advantageous when measuring small components or localized temperature points in cryogenic systems, where unwanted heat transfer through the sensor wiring can affect the measurement.

Actual thermal performance depends on conductor length, mounting method, junction dimensions and the surrounding thermal environment.

6. Compact and Flexible Integration

The flat parallel conductor arrangement provides a compact profile for integration into confined measurement spaces.

The assembly can be used in cryostat fixtures, cold-stage measurement systems, vacuum chamber testing arrangements and customized laboratory temperature probes.

Each piece is supplied in a standard length of 20 cm (200 mm), with customized lengths available upon request.

Technical Specifications

Parameter Specification
Product Name Type T Bifilar Thermocouple Wire
Thermocouple Type Type T
Reference Standard IEC 60584 / Applicable Type T reference tables
Positive Conductor (+) Copper (Cu)
Positive Insulation Color Blue
Negative Conductor (-) Constantan (Cu-Ni Alloy, CuNi45)
Negative Insulation Color Red
Wire Gauge 40 AWG
Conductor Diameter 0.003 inch / 0.076 mm per leg, as specified
Wire Construction Bifilar, parallel side-by-side configuration
Hot Junction Factory-welded bead
Hot Junction Diameter Subject to actual production specification
Standard Length 20 cm (200 mm) per piece
Length Tolerance ±3 mm, subject to production confirmation
Typical Application Cryogenic and low-temperature measurement

Note: The specified conductor diameter should be confirmed as the bare conductor diameter or insulated outside diameter. Actual usable temperature limits depend on conductor material quality, insulation grade, junction protection and application conditions.

Typical Cryogenic and Low-Temperature Applications

This miniature Type T thermocouple assembly can be integrated into a variety of low-temperature research and industrial measurement systems.

1. Liquid Nitrogen and Cryogenic Systems

  • Liquid nitrogen temperature monitoring

  • Dewar temperature measurement assemblies

  • Cryogenic cooling system verification

  • Cold-stage temperature measurement

  • Cryogenic sample cooling experiments

  • Low-temperature thermal cycling tests

2. Cryostat and Laboratory Research

  • Cryostat stage temperature monitoring

  • Cold finger temperature measurement

  • Vacuum chamber temperature sensing

  • Low-temperature physics experiments

  • Cryogenic research instrumentation

  • Laboratory temperature comparison and testing

3. Superconducting and Scientific Equipment

  • Superconducting magnet temperature monitoring

  • Superconducting equipment thermal testing

  • Detector cooling system monitoring

  • Cryogenic instrumentation development

  • Scientific instrument temperature validation

  • Specialized low-temperature research assemblies

4. Industrial and Biological Applications

  • Freeze-drying and lyophilization temperature monitoring

  • Biological sample storage temperature verification

  • Pharmaceutical cold storage equipment testing

  • Laboratory refrigeration systems

  • Low-temperature process validation

  • Specialized cooling and thermal management systems

For applications approaching liquid helium temperatures or below -200°C, conductor material composition, thermoelectric calibration and insulation suitability should be specifically evaluated before use.

Installation and Integration Recommendations

For reliable cryogenic temperature measurements, proper junction attachment and thermal management are important.

Recommended integration considerations include:

  • Ensure good thermal contact between the welded hot junction and the measurement target.

  • Use adhesives, varnishes or encapsulation materials specifically qualified for the intended cryogenic temperature range.

  • Keep the two conductors together during installation to help minimize the effective electrical loop area.

  • Minimize unnecessary heat conduction from the warm end of the lead to the cold measurement stage.

  • Select suitable vacuum-compatible feedthroughs and insulation materials where required.

  • Maintain appropriate reference junction conditions and cold-junction compensation at the measurement instrument.

  • Consider electromagnetic shielding and grounding requirements in installations involving magnet power supplies and RF equipment.

For repeated thermal cycling, the junction attachment, insulation and conductor strain relief should be evaluated for mechanical and thermal compatibility.

Quality Control and Traceability

Each production batch can be inspected according to agreed customer specifications, including:

  • Conductor diameter and dimensional inspection

  • Insulation appearance and color verification

  • Electrical continuity testing

  • Positive and negative polarity verification

  • Welded junction appearance and integrity inspection

  • Thermoelectric conformity testing

  • Finished length inspection

  • Production batch identification and traceability

Batch-related inspection records and thermoelectric test documentation can be provided according to agreed quality requirements.

For applications requiring enhanced low-temperature measurement accuracy, additional calibration at specified temperature points can be discussed according to the customer's calibration protocol.

Packaging and OEM Customization

The standard product can be supplied in individual moisture-barrier packaging with batch identification.

Customization options can be discussed based on:

  • Wire gauge and conductor diameter

  • Copper and Constantan material specifications

  • Insulation material and color

  • Bifilar parallel conductor construction

  • Welded junction dimensions

  • Finished wire length and dimensional tolerance

  • Low-temperature insulation requirements

  • Pre-stripped or customized termination options

  • Specialized packaging and batch identification

We support customized miniature Type T thermocouple assemblies for cryogenic equipment manufacturers, scientific instrument suppliers, low-temperature research laboratories and temperature sensor manufacturers.

Please share your operating temperature range, mounting method and technical requirements so our engineering team can evaluate a suitable configuration for your application.

Evaluation samples are available upon request. Contact us for technical consultation and quotation.